Summary for Test 2024-06-10-80-6

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995155
DEA: 040Q8104
EFIS: 0418000158
DIST-CO-RTE-PM04-NAP-121-16.0
Award Date12/29/2023
Closeout Date01/09/2025
Work DescriptionREPAIR PAVEMENT, REPLACE DRAINAGE SYSTEMS, AND REPLACE GUARDRAIL.
Location DescriptionNAPA COUNTY AT CIRCLE OAKS AT WOODEN VALLEY ROAD
QA Service Level1 (Verified on 11/06/2023)

Sample Information

Sample Taken Date06/10/2024 Sample Unique Key80
Date that the sample was received by the laboratory/organization performing the testing06/10/2024 Sample typeQuality Assurance
A brief description of the sample1/2" HMA 15%rap RAP The quantity of what the sample constitutesProduction Startup first 750 tons
From where was the sample collectedSupplier First name of sampler or witnessed byDaniel
Last name of sampler or witnessed byRingler Title of samplerLab Technician
Telephone number of sampler7078161520 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Vallejo Batch Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix Number320914
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-06-10-80
DIME Test ID: 2024-06-10-80-6
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-06-17

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 06/14/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1627.9 g
Mass Loss: 132.6 g
Correction Factor (Percent by mass of HMA Specimen): 1.70 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 6.26 %
General comments (publicly viewable) (Max 1000 characters): Mix burn #2

Test was verified on 6/17/2024 ✔