Summary for Test 2024-06-10-45-1
Test performed: ASTM C39-18Project Information
| Project Identifiers | Project ID: 994309 DEA: 033H5404 EFIS: 0318000012 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-70-46.0/47.0 |
| Award Date | 02/10/2023 |
| Closeout Date | Not set |
| Work Description | RAISE ALIGNMENT, PLACE HMA, STRUCTURAL CONCRETE & BRIDGE RAIL. |
| Location Description | BUTTE COUNTY NEAR PARADISE FROM 0.8 MILE WEST OF SHADY REST AREA TO 0.2 MILE EAST OF SHADY REST AREA |
| QA Service Level | 1 (Verified on 10/04/2022) |
Sample Information
| Sample Taken Date | 06/10/2024 | Sample Unique Key | 45 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/11/2024 |
| Sample type | Acceptance | A brief description of the sample | concrete |
| The quantity of what the sample constitutes | 36 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Nicholas | Last name of sampler or witnessed by | McLean |
| Title of sampler | Assistant Structures Representative | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Mathews Readymix | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Pulga Wall 2 | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | G7215PA |
|---|---|---|---|
| The truck number from where the sample was collected | 745 | The batch plant ticket number from where the sample was collected | 16027031 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | CHUTE OF TRUCK | Where the material sample would have been placed if not sampled | Wall 2 - 255' - 391' |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-06-10-45
DIME Test ID: 2024-06-10-45-1
Testing Lab: CT D03 - Chico Field Laboratory
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-06-17
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Brad McKeehan
Date of test: 06/17/2024
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 34200 lb
Maximum load on cylinder 2: 37310 lb
Maximum load on cylinder 3: 36810 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 2720.8 psi
Compressive strength of cylinder 2: 2968.2 psi
Compressive strength of cylinder 3: 2928.4 psi
Compressive strength (to nearest 10 psi): 2870 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/17/2024 ✔