Summary for Test 2024-06-03-69-2

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 994051
DEA: 041Q5814
EFIS: 0421000262
DIST-CO-RTE-PM04-SM-101-0.0-6.5
Award Date01/10/2024
Closeout DateNot set
Work DescriptionREHABILITATE PAVEMENT AND UPGRADE MEDIAN BARRIER [PS&E E-COPY AVAILABLE UPON REQUEST]
Location DescriptionSAN MATEO COUNTY FROM SAN MATEO COUNTY LINE IN EAST PALO ALTO TO WHIPPLE AVENUE IN REDWOOD CITY
QA Service Level1 (Verified on 07/05/2022)

Sample Information

Sample Taken Date06/03/2024 Sample Unique Key69
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/04/2024
Sample typeProduction Start-Up A brief description of the sample1/2 RHMA-G
The quantity of what the sample constitutes100 Tons From where was the sample collectedSupplier
First name of sampler or witnessed byHolie Last name of sampler or witnessed bySada
Title of samplerPlant QC Tech Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials Co - Pleasanton Transportation Laboratory (TL) NumberC690426
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0010
The fabricator's/manufacturer's product name for the sampleMD 326122 The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant Sampler
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberD04-JMF-22-041 Lot number1
Sublot number1 Aggregate Mix Number

Test Details

DIME Sample ID: 2024-06-03-69
DIME Test ID: 2024-06-03-69-2
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-06-17

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Luis Magana
Date of test: 06/04/2024
Clay Level (Test 1): 7.7
Sand Level (Test 1): 3.8
Clay Level (Test 2): 7.5
Sand Level (Test 2): 3.7
Clay Level (Test 3): 7.2
Sand Level (Test 3): 3.5
Sand Equivalent (Test 1): 50
Sand Equivalent (Test 2): 50
Sand Equivalent (Test 3): 49
Sand Equivalent: 50
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/17/2024