Summary for Test 2024-06-07-46-3
Test performed: ASTM D5329-16Project Information
| Project Identifiers | Project ID: 1000382 DEA: 030N3504 EFIS: 0324000094 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-5-25/28 |
| Award Date | 10/18/2023 |
| Closeout Date | 09/03/2025 |
| Work Description | Deck rehab with RSC. New Approach Slabs. New Barriers. |
| Location Description | Br 24-0207L/R. Br 24-0068L |
| QA Service Level | 1 (Verified on 06/11/2024) |
Sample Information
| Sample Taken Date | 06/07/2024 | Sample Unique Key | 46 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/07/2024 |
| Sample type | Verification | A brief description of the sample | 3/4 RHMA-G PG64-16 |
| The quantity of what the sample constitutes | 4 cans | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | James | Last name of sampler or witnessed by | Brewster |
| Title of sampler | MREA | Telephone number of sampler | |
| Laboratory sample identification | 024-034 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Granite - Bradshaw | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | Valero Benicia |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2024-06-07-46
DIME Test ID: 2024-06-07-46-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2024-06-13
Test Results
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 06/13/2024
Temperature: 25 C
Ball Penetration (P1): 0 mm
Final Dial reading (F1): 60 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F2): 61 mm
Ball Penetration (P3): 0 mm
Final Dial reading (F3): 64 mm
Resilience 1: 40 %
Resilience 2: 39 %
Resilience 3: 36 %
Average Resilience: 38 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/13/2024 ✔