Summary for Test 2024-06-13-11-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 1000245
DEA: 072XN104
EFIS: 0724000222
DIST-CO-RTE-PM07-VEN-150-
Award DateNot set
Closeout DateNot set
Work DescriptionRetaining wall repair due to landslide emergency at Route 150 in Santa Paula.
Location DescriptionRoute 150 in Santa Paula.
QA Service Level1 (Verified on 04/05/2024)

Sample Information

Sample Taken Date06/13/2024 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing06/13/2024 Sample typeAcceptance
A brief description of the sampleStructural Backfill The quantity of what the sample constitutes60 SF
From where was the sample collectedJob Site First name of sampler or witnessed byMichelangelo
Last name of sampler or witnessed bySese Title of samplerTET
Telephone number of sampler310-345-6204 Laboratory sample identification24-1474
Linked DIME Sample ID The fabricator/manufacturer/facility nameNA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleStructural Backfill
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedVarious locations
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2024-06-13-11
DIME Test ID: 2024-06-13-11-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-06-13

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 06/13/2024
Gage No.: 30936
Test No.: no data
Nuclear By: Michelangelo Sese
Non-Bias Plan No.: Random
Depth: 12
Material No.: no data
Material Type: Structural Backfill
Impact By: Michelangelo Sese
Standard Count Density: 1853 g/cc
Count or Density 1: 1.99 g/cc
Count or Density 2: 1.74 g/cc
Count or Density 3: 1.88 g/cc
Standard Count Moisture: 555 g/cc
Moisture Count 1: 0.31 g/cc
Moisture Count 2: 0.27 g/cc
Moisture Count 3: 0.25 g/cc
Sum of Count or Density: 5.61 g/cc
Average of Count or Density: 1.87 g/cc
Sum of Moisture Count: 0.83 g/cc
Average of Moisture Count: 0.28 g/cc
Calculated Percent Relative Compaction: 89 %
Reported Percent Relative Compaction: 896 %
General comments (publicly viewable) (Max 1000 characters): Rte. 150 @ Santa Paula PM 31.36

Test was verified on 6/13/2024 ✔