Summary for Test 2024-05-06-76-4
Test performed: AASHTO T315-22Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/06/2024 | Sample Unique Key | 76 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/06/2024 |
Sample type | Quality Control | A brief description of the sample | Tank 1 |
The quantity of what the sample constitutes | 1 of 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Keven | Last name of sampler or witnessed by | Heitschmidt |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | PG58225624T1 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Chowchilla, CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Albina Asphalt - Chowchilla CA | Multigrade | Yes |
Multigrade Type | PG 58-22 / PG 58-16 | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-05-06-76
DIME Test ID: 2024-05-06-76-4
Testing Lab: Albina Asphalt
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-06-13
Test Results
Phase: Original binder
Input Type: Calculated
Tester's full name: Reeve P
Date of test: 06/13/2024
Phase Angle (δ) (for the 10 cycles): no data
Dynamic Shear, G*/sin(δ): 1.65 kPa
General comments (publicly viewable) (Max 1000 characters): Submitted from ASCP bulk upload.
Test was verified on 6/13/2024 ✔