Summary for Test 2024-05-31-19-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 994327 DEA: 081G4704 EFIS: 0816000001 |
---|---|
DIST-CO-RTE-PM | 08-RIV-74-3.1/53.5 |
Award Date | 01/02/2023 |
Closeout Date | Not set |
Work Description | STRUCTURAL CONC BR, CONC SLAB, HMA (TYPE A), ALT CRASH CUSHION SYSTEM. |
Location Description | RIVERSIDE COUNTY NEAR LAKE ELSINORE AT MORRILL CANYON BRIDGE AND NEAR HEMET AT STRAWBERRY CREEK BRIDGE. |
QA Service Level | 1 (Verified on 06/08/2023) |
Sample Information
Sample Taken Date | 05/31/2024 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/12/2024 |
Sample type | Acceptance | A brief description of the sample | #6 ZAP SCREWLOCK SL Coupler |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Victor | Last name of sampler or witnessed by | Wami |
Title of sampler | Structure Representative | Telephone number of sampler | 951-285-0118 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | ZAP SCREWLOCK | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 56-0180 | |
Structure name | Strawberry Creek Bridge |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A615 |
Material Grade | 60 | Rebar Manufacturer | CMC Steel Arizona |
Coupler Manufacturer | Bar Splice Products | Intermediate Assembler or Fabricator | |
Rebar Size | #6 | Coupler Model | ZAP SCREWLOCK SL COUPLER |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | 73132187 | Rebar Heat Number(s) | 4137909 |
Rebar Size 2 | Coupler Unique ID | SL-21-02 |
Test Details
DIME Sample ID: 2024-05-31-19
DIME Test ID: 2024-05-31-19-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-06-14
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 06/13/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID:
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 2 | No. 6/19mm | 1 | 0 | 0.44 | 38780 | 88137 | Service Splice | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 6/14/2024 ✔