Summary for Test 2024-05-29-69-1

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 995037
DEA: 061E8004
EFIS: 0622000086
DIST-CO-RTE-PM06-TUL-63-21.7/R24.3
Award Date10/10/2023
Closeout DateNot set
Work DescriptionPLACE SLURRY SEAL, THERMOPLASTIC TRAFFIC STRIPE AND PAVEMENT MARKING.
Location DescriptionTULARE COUNTY IN CUTLER AND OROSI FROM 0.1 MILE SOUTH OF AVENUE 402 TO AVENUE 422
QA Service Level1 (Verified on 08/07/2023)

Sample Information

Sample Taken Date05/29/2024 Sample Unique Key69
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/11/2024
Sample typeVerification A brief description of the samplePMCQS-1H
The quantity of what the sample constitutes2 jar of PMCQS-1H From where was the sample collectedSource
First name of sampler or witnessed byQG Last name of sampler or witnessed byUnknown
Title of samplerQC Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVSS Emultech Transportation Laboratory (TL) NumberC754872
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradePMCQS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2024-05-29-69
DIME Test ID: 2024-05-29-69-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2024-06-12

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 06/12/2024
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 154.0 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 121.9 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 154.3 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 122.2 g
Beaker 1 Residue: 64.2 %
Beaker 2 Residue: 64.2 %
Percentage of residue: 64 %
General comments (publicly viewable) (Max 1000 characters): EVAP

Test was verified on 6/12/2024