Summary for Test 2024-04-24-104-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995054 DEA: 024H0204 EFIS: 0218000069 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-36-20.0/39.7 |
| Award Date | 10/23/2023 |
| Closeout Date | 07/03/2025 |
| Work Description | PLACE RHMA AND HMA, CORRECT SEGMENTS, AND REPLACE AC SURFACING. |
| Location Description | TEHAMA COUNTY NEAR RED BLUFF FROM 0.8 MILE EAST OF SALT CREEK BRIDGE TO BAKER ROAD |
| QA Service Level | 1 (Verified on 08/14/2023) |
Sample Information
| Sample Taken Date | 04/24/2024 | Sample Unique Key | 104 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/23/2024 | Sample type | Acceptance |
| A brief description of the sample | 4 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28 M) | The quantity of what the sample constitutes | 50 tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Brandon |
| Last name of sampler or witnessed by | White | Title of sampler | TET NRC |
| Telephone number of sampler | Laboratory sample identification | D79474 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) | |
| Transportation Laboratory (TL) Number | 035786 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-04-24-104
DIME Test ID: 2024-04-24-104-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-06-11
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 06/03/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3062.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 5161.1 g
Mass of HMA Sample prior to ignition: 2098.4 g
Mass Loss: 122.4 g
Mass of aggregate remaining after ignition: 1976.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.79 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.90 %
General comments (publicly viewable) (Max 1000 characters): Pb=4.90%
Test was verified on 6/11/2024 ✔