Summary for Test 2024-06-06-64-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993382 DEA: 031H2404 EFIS: 0316000077 |
---|---|
DIST-CO-RTE-PM | 03-PLA-49-2.2/2.4 |
Award Date | 05/27/2022 |
Closeout Date | Not set |
Work Description | REALIGN ROADWAY, CONSTRUCT ROUNDABOUT AND RELOCATE SEWER LINES. |
Location Description | PLACER COUNTY IN AUBURN FROM 0.1 MILE SOUTH OF THE INTERSECTION OF ROUTE 49 AND LINCOLN WAY / BORLAND AVENUE TO LINCOLN WAY |
QA Service Level | 1 (Verified on 11/08/2021) |
Sample Information
Sample Taken Date | 06/06/2024 | Sample Unique Key | 64 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/10/2024 |
Sample type | Quality Assurance | A brief description of the sample | 2 Boxes HMA |
The quantity of what the sample constitutes | 3/4" HMA-SP w/ 15%RAP | From where was the sample collected | Source |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Drane |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Daily 24-030 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Teichert Hallwood | Transportation Laboratory (TL) Number | C765373 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number |
Test Details
DIME Sample ID: 2024-06-06-64
DIME Test ID: 2024-06-06-64-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-06-10
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 06/10/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2157.9 g
Mass Loss: 109.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.51 %
Moisture Content: 0 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.56 %
General comments (publicly viewable) (Max 1000 characters): Daily 24-030
JMF 24-004
Test was verified on 6/10/2024 ✔