Summary for Test 2024-06-04-40-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 995085
DEA: 07322904
EFIS: 0716000059
DIST-CO-RTE-PM07-LA-27-0.0/18.6
Award Date11/06/2023
Closeout DateNot set
Work DescriptionREMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
QA Service Level1 (Verified on 09/11/2023)

Sample Information

Sample Taken Date06/04/2024 Sample Unique Key40
Date that the sample was received by the laboratory/organization performing the testing06/05/2024 Sample typeAcceptance
A brief description of the sample1 x 4 PCC Aggregate The quantity of what the sample constitutes51 CY
From where was the sample collectedManufacturer First name of sampler or witnessed byHonesto
Last name of sampler or witnessed byCastillo Title of samplerMREAS
Telephone number of sampler2134537563 Laboratory sample identification022A
Linked DIME Sample ID2024-06-04-43 The fabricator/manufacturer/facility nameContractor Staging Yard
Transportation Laboratory (TL) NumberC006790 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedContractor Staging Yard Stockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberCTS-30-EHI Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-06-04-40
DIME Test ID: 2024-06-04-40-1
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-06-12

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Honesto Castillo
Date of test: 06/05/2024
Sieve SizeCumulative Percent Passing
100 %
100 %
100 %
100 %
97 %
82 %
59 %
51 %
45 %
39 %
32 %
23 %
10 %
2 %
0.6 %
General comments (publicly viewable) (Max 1000 characters): Combined Gradation: 2024-06-04-40(55%): 2024-06-04-43(45%)

Test was verified on 6/12/2024