Summary for Test 2024-05-30-63-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214708
DEA: 07323904
EFIS: 0716000072
DIST-CO-RTE-PM07---
Award Date03/27/2023
Closeout DateNot set
Work DescriptionCOLD PLANE AC, PLACE RUBBERIZED HOT MIX AS
Location DescriptionVENTURA COUNTY NEAR VENTURA FROM ROUTE 1/101 SEPARATION TO MOBIL PIER ROAD.
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date05/30/2024 Sample Unique Key63
Date that the sample was received by the laboratory/organization performing the testing06/03/2024 Sample typeAcceptance
A brief description of the sample1/2" RHMA-G 326122 SAT VLO The quantity of what the sample constitutes750 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byMD
Last name of sampler or witnessed byShahjahan Title of samplerMREA
Telephone number of sampler Laboratory sample identification24-105
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials Saticoy
Transportation Laboratory (TL) Number019545 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number326122 SAT VLO
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-05-30-63
DIME Test ID: 2024-05-30-63-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-06-10

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 06/04/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4023.3 g
Mass of the specimen and specimen basket assembly prior to ignition: 5568.9 g
Mass of HMA Sample prior to ignition: 1545.6 g
Mass Loss: 116.3 g
Mass of aggregate remaining after ignition: 1429.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.07 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.45 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/10/2024 ✔