Summary for Test 2024-05-09-78-3
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 993409 DEA: 07327604 EFIS: 0716000132 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-39-32.2/38.4 |
| Award Date | 03/07/2022 |
| Closeout Date | 08/19/2025 |
| Work Description | INSTALL GUARDRAILS AND CONSTRUCT RETAINING WALLS. |
| Location Description | LOS ANGELES COUNTY NEAR AZUSA AT VARIOUS LOCATIONS FROM 0.3 MILE SOUTH OF NORTH FORK SAN GABRIEL RIVER OVERCROSSING TO 0.3 MILE NORTH CRYSTAL LAKE ROAD |
| QA Service Level | 1 (Verified on 12/06/2021) |
Sample Information
| Sample Taken Date | 05/09/2024 | Sample Unique Key | 78 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2024 |
| Sample type | Acceptance | A brief description of the sample | 4X8 PCC cylinders |
| The quantity of what the sample constitutes | 130 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Loc | Last name of sampler or witnessed by | Nguyen |
| Title of sampler | Assistant Structure Representative | Telephone number of sampler | |
| Laboratory sample identification | 24-082 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Robertsons Redlands | Transportation Laboratory (TL) Number | 07-327604-01 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SC675B34 |
|---|---|---|---|
| The truck number from where the sample was collected | 13 | The batch plant ticket number from where the sample was collected | 826931 |
| Concrete batch plant | Robertsons Redlands | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | truck chute | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-05-09-78
DIME Test ID: 2024-05-09-78-3
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-06-06
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 06/06/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 74223 lb
Maximum load on cylinder 2: 71268 lb
Maximum load on cylinder 3: 70595 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 5876.7 psi
Compressive strength of cylinder 2: 5642.8 psi
Compressive strength of cylinder 3: 5589.5 psi
Compressive strength (to nearest 10 psi): 5700 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/6/2024 ✔