Summary for Test 2024-05-21-92-4
Test performed: AASHTO T51-22Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/21/2024 | Sample Unique Key | 92 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/04/2024 |
Sample type | Verification | A brief description of the sample | Tank 501 |
The quantity of what the sample constitutes | 1 of 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Thomas | Last name of sampler or witnessed by | Ludlum |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 24-113 | Linked DIME Sample ID | 2024-05-21-65 |
The fabricator/manufacturer/facility name | Glendale, AZ | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Holly Frontier Asphalt Company - Glendale AZ | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-05-21-92
DIME Test ID: 2024-05-21-92-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2024-06-14
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 06/06/2024
Ductility of test #1 (D1): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): DUCTILITY
Test was verified on 6/14/2024 ✔