Summary for Test 2024-05-30-59-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993424
DEA: 04281204
EFIS: 0400000769
DIST-CO-RTE-PM04-NAP-29,221-5.5/6.7,0.0/0.2
Award Date03/21/2022
Closeout DateNot set
Work DescriptionHMA, RDWY EXCAVATION, STRUCTURAL CONC AND MODIFYING LIGHTING SYSTEMS.
Location DescriptionNAPA COUNTY NEAR NAPA ON ROUTE 29 FROM 0.7 MILE SOUTH TO 0.5 MILE NORTH OF ROUTE 221 AND ON ROUTE 221 FROM 0.2 MILE NORTH OF ROUTE 29 TO ROUTE 29
QA Service Level1 (Verified on 12/08/2021)

Sample Information

Sample Taken Date05/30/2024 Sample Unique Key59
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/31/2024
Sample typeQuality Assurance A brief description of the sample3/4-INCH HMA Type A and B
The quantity of what the sample constitutes2170 Grams From where was the sample collectedSupplier
First name of sampler or witnessed byNick Last name of sampler or witnessed byHALL
Title of samplerLab Technician Telephone number of sampler7072999133
Laboratory sample identificationCon_24_374 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Vallejo Drier Drum Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number220991W

Test Details

DIME Sample ID: 2024-05-30-59
DIME Test ID: 2024-05-30-59-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-06-12

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 05/31/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2169.5 g
Mass Loss: 186.4 g
Correction Factor (Percent by mass of HMA Specimen): 2 %
Moisture Content: 0 %
Temperature Compensation Factor: 0.1 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 6.49 %
General comments (publicly viewable) (Max 1000 characters): Production Start-Up Vulcan Vallejo Drier Drum Plant

Test was verified on 6/12/2024