Summary for Test 2024-04-10-36-6

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 994332
DEA: 11430444
EFIS: 1118000204
DIST-CO-RTE-PM11-IMP-8,78-Var
Award Date12/22/2022
Closeout DateNot set
Work DescriptionREHABILITATE BRIDGES, CONCRETE BARRIERS, TERMINAL SYSTEMS, ELECTRICAL.
Location DescriptionIMPERIAL COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 02/21/2023)

Sample Information

Sample Taken Date04/10/2024 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/11/2024
Sample typeQuality Assurance A brief description of the sample1/2" HMA JMFR
The quantity of what the sample constitutes2 bags From where was the sample collectedSource
First name of sampler or witnessed byJoe Last name of sampler or witnessed byLoper
Title of sampler Telephone number of sampler
Laboratory sample identification8808-JMFR Linked DIME Sample ID
The fabricator/manufacturer/facility nameAPI Gateway Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)N/A
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number1
Sublot number1 Aggregate Mix Number

Test Details

DIME Sample ID: 2024-04-10-36
DIME Test ID: 2024-04-10-36-6
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2024-06-07

Test Results


Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 06/06/2024
Mass of saturated surface dry sample (before pycnometer) (S): 503.5 grams
Mass of the pycnometer with water and aggregate (C): 996.4 grams
Mass of the pycnometer with water (B): 680.3 grams
Mass of the oven dried sample (before pycnometer) (A): 498.7 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 503.5 grams
Mass of the oven dry aggregate (for absorption) (A): 498.7 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.661
Bulk specific gravity (SSD Basis): 2.687
Apparent specific gravity: 2.731
Absorption: 1 %
General comments (publicly viewable) (Max 1000 characters): Complies

Test was verified on 6/7/2024