Summary for Test 2024-05-24-25-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214486 DEA: 080K1224 EFIS: 0815000244 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-R28.6/37.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT |
Location Description | SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 05/24/2024 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/28/2024 |
Sample type | Acceptance | A brief description of the sample | 1" HMA-A-SP R25 1% LSM |
The quantity of what the sample constitutes | 4 BOXES OF HAMA, 1QT OF OIL | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | AREERATTANA | Last name of sampler or witnessed by | Sirisujarittham |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0266A-24 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Blue Diamond Materials-Victorville | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1 inch | Lot number | 3 |
Sublot number | 97 | HMA Mix Number | 300222 CPC R25 |
Test Details
DIME Sample ID: 2024-05-24-25
DIME Test ID: 2024-05-24-25-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-06-05
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 05/30/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 3177.7 g
Mass Loss: 143.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.56 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.09 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 3.86 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/5/2024 ✔