Summary for Test 2024-06-04-6-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 995240 DEA: 060X3804 EFIS: 0618000060 |
---|---|
DIST-CO-RTE-PM | 06-KER-166-0.0/10.2 |
Award Date | 02/28/2024 |
Closeout Date | Not set |
Work Description | COLD PLANE, PLACE HMA AND CONCRETE PAVEMENT, MODIFY DRAINAGE SYSTEM. |
Location Description | KERN COUNTY IN AND NEAR MARICOPA FROM SOUTH JUNCTION ROUTE 33 TO 2.3 MILES WEST OF SAN EMIGDIO CREEK BRIDGE |
QA Service Level | 1 (Verified on 04/02/2024) |
Sample Information
Sample Taken Date | 06/04/2024 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/04/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA |
The quantity of what the sample constitutes | 10 boxes HMA type A , 4 bags of aggregate | From where was the sample collected | Source |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Klinker |
Title of sampler | Materials Tester | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Griffith Edmonston | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 5 | HMA Mix Number |
Test Details
DIME Sample ID: 2024-06-04-6
DIME Test ID: 2024-06-04-6-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-06-04
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 06/04/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4190.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 6431.7 g
Mass of HMA Sample prior to ignition: 2240.8 g
Mass Loss: 120.9 g
Mass of aggregate remaining after ignition: 2119.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.44 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.96 %
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
06-0X3804_37041_240604_L1SL5_T308 | 104.49 KB | 06/04/2024 | 2024-06-04-6-2 | Info |
Test was verified on 6/4/2024 ✔