Summary for Test 2017-06-20-3-10
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 211588 DEA: 030F3104 EFIS: 0300000078 |
---|---|
DIST-CO-RTE-PM | 03-ED-49-23.6/24.5 |
Award Date | 12/12/2016 |
Closeout Date | 01/08/2019 |
Work Description | REPLACE BRIDGE. |
Location Description | EL DORADO COUNTY NEAR COLOMA FROM 0.1 MILE EAST OF MARSHALL ROAD TO 0.3 MILE EAST OF LOTUS ROAD |
QA Service Level | 1 (Verified on 10/19/2016) |
Sample Information
Sample Taken Date | 06/20/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/20/2017 |
Sample type | Verification | A brief description of the sample | 3/4 x 5 1/2 A325 bolt,nut,washer |
The quantity of what the sample constitutes | 9 and 12 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
Title of sampler | CA METS QA Inspector | Telephone number of sampler | (801) 669-2984 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-063-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
---|---|---|---|
Heat Number(s) | Bolt NF16100930, nut 20388020, FW 542102 | Nut Mfg. Lot Number(s) | Decker 15-40-006 |
Washer Mfg. Lot Number(s) | D2020 | Bolt Specification | A325 |
Bolt Length(s) | 5 1/2" | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 3/4" x 5 1/2" | Bolt Mfg. Lot Number | G8505 |
Rocap Test Requirement(s) | none | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-06-20-3
DIME Test ID: 2017-06-20-3-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-07-05
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/28/2017
UTM: 400KIP
Temperature: 71
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1C | A449 7/8\" x 28\" Bolt 10 Deg Wedge | 0.462 | 61887 | 275 | 133955 | 126627 | 58502 | A449 Headed Bolt w/10 Degree Wedge |
General comments (publicly viewable) (Max 1000 characters): A449 Headed Bolt w/10 Degree Wedge
Test Graph
Source: Partner Data Point FileTest was verified on 6/28/2017 ✔