Summary for Test 2024-05-29-44-2

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 214708
DEA: 07323904
EFIS: 0716000072
DIST-CO-RTE-PM07---
Award Date03/27/2023
Closeout DateNot set
Work DescriptionCOLD PLANE AC, PLACE RUBBERIZED HOT MIX AS
Location DescriptionVENTURA COUNTY NEAR VENTURA FROM ROUTE 1/101 SEPARATION TO MOBIL PIER ROAD.
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date05/29/2024 Sample Unique Key44
Date that the sample was received by the laboratory/organization performing the testing05/29/2024 Sample typeQuality Assurance
A brief description of the sample1/2" RHMA-G The quantity of what the sample constitutes0-750 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byAvo
Last name of sampler or witnessed byKarajian Title of samplerPlant Inspector
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials HMA - Saticoy
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0020, 91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant numberVulcan Saticoy HMA A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number326122 SAT VLO Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-05-29-44
DIME Test ID: 2024-05-29-44-2
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-06-03

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Avo Karajian
Date of test: 05/31/2024
Clay Level (Test 1): 4.7
Sand Level (Test 1): 3.8
Clay Level (Test 2): 4.7
Sand Level (Test 2): 3.7
Clay Level (Test 3): 4.7
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 81
Sand Equivalent (Test 2): 79
Sand Equivalent (Test 3): 81
Sand Equivalent: 81
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/3/2024 ✔