Summary for Test 2024-05-08-48-5

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 994296
DEA: 07336004
EFIS: 0716000375
DIST-CO-RTE-PM07-VEN-118-R1.4/1.8
Award Date12/07/2022
Closeout DateNot set
Work DescriptionCONSTRUCT STORMWATER TREATMENT DEVICES.
Location DescriptionIN VENTURA COUNTY NEAR SATICOY FROM 0.2 MILE EAST OF NARDO STREET TO 0.1 MILE WEST OF SANTA CLARA RIVER
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date05/08/2024 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/13/2024
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R25 No LAS
The quantity of what the sample constitutes3 Bags Of Combined Agg., 1 Bag Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byVictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler
Laboratory sample identification0241A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite-Santa Paula Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Granite Santa Paula Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number14342 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-05-08-48
DIME Test ID: 2024-05-08-48-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-06-26

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Satish Jain
Date of test: 05/17/2024
Clay Level (Test 1): 5
Sand Level (Test 1): 4
Clay Level (Test 2): 4.8
Sand Level (Test 2): 4
Clay Level (Test 3): 4.8
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 80
Sand Equivalent (Test 2): 84
Sand Equivalent (Test 3): 80
Sand Equivalent: 82
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/26/2024