Summary for Test 2024-05-08-48-2

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 994296
EFIS: 0716000375
DIST-CO-RTE-PM07-VEN-118-R1.4/1.8
Award Date12/07/2022
Closeout Date01/21/2026
Work DescriptionCONSTRUCT STORMWATER TREATMENT DEVICES.
Location DescriptionIN VENTURA COUNTY NEAR SATICOY FROM 0.2 MILE EAST OF NARDO STREET TO 0.1 MILE WEST OF SANTA CLARA RIVER
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date05/08/2024 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/13/2024
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R25 No LAS
The quantity of what the sample constitutes3 Bags Of Combined Agg., 1 Bag Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byVictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler
Laboratory sample identification0241A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite-Santa Paula Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Granite Santa Paula Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number14342 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-05-08-48
DIME Test ID: 2024-05-08-48-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2024-06-20

Test Results


Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 05/15/2024
Mass of saturated surface dry sample (before pycnometer) (S): 500.0 grams
Mass of the pycnometer with water and aggregate (C): 968.1 grams
Mass of the pycnometer with water (B): 655.9 grams
Mass of the oven dried sample (before pycnometer) (A): 495.8 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.0 grams
Mass of the oven dry aggregate (for absorption) (A): 495.8 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.640
Bulk specific gravity (SSD Basis): 2.662
Apparent specific gravity: 2.700
Absorption: 0.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/20/2024