Summary for Test 2017-06-14-5-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 211669 DEA: 022C0904 EFIS: 0200000161 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-50.6/51.7 |
| Award Date | 11/16/2016 |
| Closeout Date | 11/12/2020 |
| Work Description | BRIDGE WIDENING AND DECK REPLACEMENT, HMA, MGS AND CULVERT REPLACEMENT |
| Location Description | PLUMAS COUNTY NEAR QUINCY FROM 0.6 MILE WEST TO 0.5 MILE EAST OF SPRING GARDEN BRIDGE OVERHEAD |
| QA Service Level | 1 (Verified on 10/25/2016) |
Sample Information
| Sample Taken Date | 06/14/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/20/2017 |
| Sample type | Verification | A brief description of the sample | A325 HDG |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | (801) 669-2984 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-062-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
|---|---|---|---|
| Heat Number(s) | NF15203956 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | A325 HDG | |
| Bolt Length(s) | 4" | Nut Specification | n/a |
| Washer Specification | n/a | Finish | HDG |
| Diameter/Size | 1/2" x 4" | Bolt Mfg. Lot Number | 372481A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-06-14-5
DIME Test ID: 2017-06-14-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-07-05
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/27/2017
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 5A | B76-061-17 | 1/2\" | 19861 | 88.3 | 10 | A325 | Brian |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 6/28/2017 ✔