Summary for Test 2017-06-14-7-2
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 211669 DEA: 022C0904 EFIS: 0200000161 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-50.6/51.7 |
| Award Date | 11/16/2016 |
| Closeout Date | 11/12/2020 |
| Work Description | BRIDGE WIDENING AND DECK REPLACEMENT, HMA, MGS AND CULVERT REPLACEMENT |
| Location Description | PLUMAS COUNTY NEAR QUINCY FROM 0.6 MILE WEST TO 0.5 MILE EAST OF SPRING GARDEN BRIDGE OVERHEAD |
| QA Service Level | 1 (Verified on 10/25/2016) |
Sample Information
| Sample Taken Date | 06/14/2017 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/20/2017 | Sample type | Verification |
| A brief description of the sample | F436 HDG washer | The quantity of what the sample constitutes | 9 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Flygare | Title of sampler | CT METS QA INSPECTOR |
| Telephone number of sampler | (801) 669-2984 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | UIS |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-062-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
|---|---|---|---|
| Heat Number(s) | B40065 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | D2656 | Bolt Specification | n/a |
| Bolt Length(s) | Unknown | Nut Specification | n/a |
| Washer Specification | F436 HDG | Finish | HDG |
| Diameter/Size | 1/2" | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2017-06-14-7
DIME Test ID: 2017-06-14-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-07-05
Test Results
Input Type: Calculated
Tester's full name: Arnold Viken
Date of test: 06/27/2017
Sample No.: 7B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: D2656
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: F436 P
Size: no data
Bolt Length: no data
Measurement Average: 5.94 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/28/2017 ✔