Summary for Test 2024-05-20-92-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 214698 DEA: 120N8904 EFIS: 1214000130 |
---|---|
DIST-CO-RTE-PM | 12-ORA-133-8.3/M9.3 |
Award Date | 11/09/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT AUXILIARY LANE. |
Location Description | ORANGE COUNTY IN IRVINE FROM ROUTE 133/405 SEPARATION TO IRVINE CENTER DRIVE OVERCROSSING |
QA Service Level | 1 (Verified on 02/22/2021) |
Sample Information
Sample Taken Date | 05/20/2024 | Sample Unique Key | 92 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/30/2024 |
Sample type | Quality Assurance | A brief description of the sample | zap screw lock type 2 |
The quantity of what the sample constitutes | 106 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | WEI JEN | Last name of sampler or witnessed by | Lee |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Jobsite | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Cascade |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | |
Rebar Size | #8 | Coupler Model | Zap Screwlok Coupler Type 2 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | A160343 | Rebar Heat Number(s) | 447422 |
Rebar Size 2 | Coupler Unique ID | SL-17-03 |
Test Details
DIME Sample ID: 2024-05-20-92
DIME Test ID: 2024-05-20-92-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-05-30
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 05/29/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | No. 8/25mm | 2 | -0.0044 | 0.79 | 73337 | 92832 | Service Splice | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 5/30/2024 ✔