Summary for Test 2024-05-22-5-4
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 213903 DEA: 043G4544 EFIS: 0412000054 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA,SM-92-R14.4/R18.8,R0.0/R.2.4 |
| Award Date | 12/31/2019 |
| Closeout Date | 04/04/2025 |
| Work Description | Repair Spalled Concrete Columns and Spandrel Beams |
| Location Description | San Mateo-Hayward Bridge |
| QA Service Level | 1 (Verified on 01/22/2019) |
Sample Information
| Sample Taken Date | 05/22/2024 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/24/2024 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM A325 Bolt Assembly |
| The quantity of what the sample constitutes | 1320 ea | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Parr |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B373-058-24 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 1000220017 1000216350 C72845 | Nut Mfg. Lot Number(s) | W000034072 |
| Washer Mfg. Lot Number(s) | 174124 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 2-1/2” | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | HDG |
| Diameter/Size | 5/8” | Bolt Mfg. Lot Number | W000065542 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2024-05-22-5
DIME Test ID: 2024-05-22-5-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-06-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 05/29/2024
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1B | 38279 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 6/4/2024 ✔