Summary for Test 2024-05-20-3-2

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 994267
DEA: 07326204
EFIS: 0716000113
DIST-CO-RTE-PM07-LA-39-17.8
Award Date11/23/2022
Closeout Date06/10/2025
Work DescriptionCONSTRUCT BRIDGE, PLACE STRUCTURAL STEEL AND CONCRETE BARRIER.
Location DescriptionLOS ANGELES COUNTY IN AZUSA AT SAN GABRIEL RIVER BRIDGE
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date05/20/2024 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/22/2024
Sample typeQuality Assurance A brief description of the sampleASTM F3125/A325 7/8" X 6" Heavy Hex Bolt Assembly
The quantity of what the sample constitutes10 bolts From where was the sample collectedDistributor
First name of sampler or witnessed byPreston Last name of sampler or witnessed byBrockett
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler5627836180
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCordova Bolt Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL175-080-24 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)253512A-A
Heat Number(s)Bolt- 748698 Nut- 8000006661 Washer- 42350330 Nut Mfg. Lot Number(s)456888A
Washer Mfg. Lot Number(s)0224-113 Bolt SpecificationASTM A325/ F3125
Bolt Length(s)6" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishASTM A153- Hot Dip Galvanized
Diameter/Size7/8 Bolt Mfg. Lot Number253512A
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s)

Test Details

DIME Sample ID: 2024-05-20-3
DIME Test ID: 2024-05-20-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-06-03

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 05/28/2024
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A74929Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 6/3/2024