Summary for Test 2017-06-21-9-7
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/21/2017 | Sample Unique Key | 9 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/23/2017 | Sample type | Quality Assurance |
| A brief description of the sample | A449 HDG all thread | The quantity of what the sample constitutes | 3 |
| From where was the sample collected | Other | First name of sampler or witnessed by | Edward |
| Last name of sampler or witnessed by | Leach | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Portland Bolt |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | S3808017 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 24332 | |
| Washer Mfg. Lot Number(s) | Bolt Specification | F449 | |
| Bolt Length(s) | 12" | Nut Specification | A563 HDG |
| Washer Specification | na | Finish | HDG |
| Diameter/Size | 0.625 | Bolt Mfg. Lot Number | 304298 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2017-06-21-9
DIME Test ID: 2017-06-21-9-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-07-04
Test Results
Input Type: Calculated
Tester's full name: Arnold Viken
Date of test: 06/26/2017
Sample No.: 1B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 304298
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: PB A449
Size: 0.625 in
Bolt Length: 12 in
Measurement Average: 4.58 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/27/2017 ✔