Summary for Test 2024-05-28-1-2

Test performed: CTM 518-June 2010

Project Information

Project IdentifiersProject ID: 994872
DEA: 060X1604
EFIS: 0618000183
DIST-CO-RTE-PM06-KER-58-R64.4/67.3
Award Date08/29/2023
Closeout Date05/09/2025
Work DescriptionHMA (TYPE A), RHMA-G, JPCP, CRCP & HIGH SPEED WEIGH-IN-MOTION SYSTEM.
Location DescriptionKERN COUNTY NEAR EDISON FROM 0.2 MILE WEST OF TEJON HIGHWAY OVERCROSSING TO CALIENTE CREEK BRIDGE
QA Service Level1 (Verified on 06/14/2023)

Sample Information

Sample Taken Date05/28/2024 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/28/2024
Sample typeDepartment Acceptance A brief description of the sampleJPCP
The quantity of what the sample constitutes30 CY From where was the sample collectedJob Site
First name of sampler or witnessed byNeale Last name of sampler or witnessed byBrown
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHoliday Rock - Bakersfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number3FSH001
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected3
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-05-28-1
DIME Test ID: 2024-05-28-1-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Test Release Date: 2024-05-28

Test Results


Input Type: Measured
Tester's full name: Neale Brown
Date of test: 05/28/2024
Calibration factor: 4
Weight of (Measure + Concrete + Cover Plate): 45.37 lb
Weight of (Measure + Cover Plate): 8.55 lb
Total weight of cement: 5930 lb
Total weight of fine aggregate: 12575.3 lb
Total weight of coarse aggregate: 18280 lb
Total weight of water added during mixing: 2572.3 lb
Kelly Ball Penetration of the batch of concrete tested: 1.75 inch
Air content by the pressure method: 1.4 %
Station number or portion of the structure in which the concrete was placed: Sta 165+35
Net weight of concrete: 36.82 lb
Total weight of all material in the mix: 39357.6 lb
Volume of the concrete: 9.897 yd^3
Unit weight of the concrete: 147.28 lb/ft^3
Cement content: 599.171 lb/yd^3
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0X1604_37044_240528_NBpdf112.03 KB05/28/20242024-05-28-1-2   Info

Test was verified on 5/28/2024