Summary for Test 2024-05-16-4-1
Test performed: ASTM A416-18Project Information
| Project Identifiers | Project ID: 995201 DEA: 061G3104 EFIS: 0623000239 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-178-20.6/21.6 |
| Award Date | 06/02/2023 |
| Closeout Date | 12/02/2025 |
| Work Description | Roadway / retaining wall / slope repairs |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 10/06/2023) |
Sample Information
| Sample Taken Date | 05/16/2024 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/22/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 0.6 Dia. Low relax strand |
| The quantity of what the sample constitutes | 3 Samples from PK# S380570-9 HT#081724 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 916-767-3535 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-047-24 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | Uncoated |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | S380570-9 | Number of Coils | 1 |
| Group Number | Strand Diameter | .6 in | |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | 081724 | Mfg. Lot Number(s) | PK #S380570-9 |
| Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2024-05-16-4
DIME Test ID: 2024-05-16-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2024-05-31
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: AAuvinen
Date of test: 05/24/2024
UTM: 120kip
Temperature: 72 f
Extensometers: E88766
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | S0581724 | S380570-9 | 0.22 | 59675 | 55369.8 | 28.2 | 1.76 | AAuvinen |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 5/31/2024 ✔