Summary for Test 2024-05-14-84-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 995085
DEA: 07322904
EFIS: 0716000059
DIST-CO-RTE-PM07-LA-27-0.0/18.6
Award Date11/06/2023
Closeout DateNot set
Work DescriptionREMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
QA Service Level1 (Verified on 09/11/2023)

Sample Information

Sample Taken Date05/14/2024 Sample Unique Key84
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2024
Sample typeDepartment Acceptance A brief description of the sample3- 6X6X21 Rapid Set Concrete Beams
The quantity of what the sample constitutes130 CY From where was the sample collectedJob Site
First name of sampler or witnessed byRon Last name of sampler or witnessed byHernandez
Title of samplerSequoia QC Telephone number of sampler
Laboratory sample identification24-0973 Linked DIME Sample ID
The fabricator/manufacturer/facility nameShort Load Concrete Transportation Laboratory (TL) Number051424
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI-JCPC
The truck number from where the sample was collected16 The batch plant ticket number from where the sample was collectedNA
Concrete batch plantShort load concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-05-14-84
DIME Test ID: 2024-05-14-84-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-05-24

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: Yes
Input Type: Measured
Tester's full name: Robert Achuela
Date of test: 05/24/2024
Identification number: 1
Width of specimen: 6.0625 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7548 lb
Maximum load applied 2: 7426 lb
Maximum load applied 3: 7169 lb
Correction Factor: 1
Correction Factor 2: 1
Correction Factor 3: 1
Curing history and apparent moisture condition of the specimen: damp
If specimen was capped, ground or if leather shims were used: no
Defects in specimen, including numbers of beams discarded during test: no
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 640 psi
Modulus of rupture 2: 640 psi
Modulus of rupture 3: 630 psi
Modulus of rupture average: 640 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/24/2024