Summary for Test 2024-05-15-74-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994243
DEA: 044J8404
EFIS: 0416000027
DIST-CO-RTE-PM04-CC-24-R3.4/R3.6
Award Date11/28/2022
Closeout Date11/27/2024
Work DescriptionSEISMIC RESTORATION.
Location DescriptionCONTRA COSTA COUNTY IN ORINDA FROM 0.1 MILE WEST OF SAINT STEPHENS DRIVE OVERCROSSING TO 0.1 MILE EAST OF SAINT STEPHENS DRIVE OVERCROSSING.
QA Service Level1 (Verified on 09/13/2022)

Sample Information

Sample Taken Date05/15/2024 Sample Unique Key74
Date that the sample was received by the laboratory/organization performing the testing05/16/2024 Sample typeQuality Assurance
A brief description of the sample1/2-INCH RHMA-O The quantity of what the sample constitutes1658 GRAMS
From where was the sample collectedSupplier First name of sampler or witnessed byDaniel
Last name of sampler or witnessed byRingler Title of sampler
Telephone number of sampler7078161520 Laboratory sample identificationCon_24_306
Linked DIME Sample ID The fabricator/manufacturer/facility nameDe Silva Gates Sunol Drier Drum Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeOGFC
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberMD 6653
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-05-15-74
DIME Test ID: 2024-05-15-74-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-24

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 05/16/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1657.8 g
Mass Loss: 141.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.88 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.47 %
General comments (publicly viewable) (Max 1000 characters): De Silva Gates Sunol Drier Drum Plant

Test was verified on 5/24/2024 ✔