Summary for Test 2024-05-14-83-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994243 DEA: 044J8404 EFIS: 0416000027 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-24-R3.4/R3.6 |
| Award Date | 11/28/2022 |
| Closeout Date | 11/27/2024 |
| Work Description | SEISMIC RESTORATION. |
| Location Description | CONTRA COSTA COUNTY IN ORINDA FROM 0.1 MILE WEST OF SAINT STEPHENS DRIVE OVERCROSSING TO 0.1 MILE EAST OF SAINT STEPHENS DRIVE OVERCROSSING. |
| QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
| Sample Taken Date | 05/14/2024 | Sample Unique Key | 83 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/16/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2-INCH RHMA-O |
| The quantity of what the sample constitutes | 1691 GRAMS | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Ringler |
| Title of sampler | Telephone number of sampler | 7078161520 | |
| Laboratory sample identification | Con_24_305 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | De Silva Gates Sunol Drier Drum Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | OGFC |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | MD 6653 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-05-14-83
DIME Test ID: 2024-05-14-83-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-24
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 05/16/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1690.7 g
Mass Loss: 141.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.88 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.32 %
General comments (publicly viewable) (Max 1000 characters): Sample 1 of the day
Test was verified on 5/24/2024 ✔