Summary for Test 2024-05-21-58-5

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 214708
DEA: 07323904
EFIS: 0716000072
DIST-CO-RTE-PM07---
Award Date03/27/2023
Closeout DateNot set
Work DescriptionCOLD PLANE AC, PLACE RUBBERIZED HOT MIX AS
Location DescriptionVENTURA COUNTY NEAR VENTURA FROM ROUTE 1/101 SEPARATION TO MOBIL PIER ROAD.
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date05/21/2024 Sample Unique Key58
Date that the sample was received by the laboratory/organization performing the testing05/22/2024 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byEsteban
Last name of sampler or witnessed bySalgado Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Saticoy
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2024-05-21-58
DIME Test ID: 2024-05-21-58-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-06-26

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Anthony Hernandez
Date of test: 05/23/2024
Time of test: 10:10 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 79.6 %
Viscosity reading #1 (A) : 0.395 Pa-s
Viscosity reading #2 (B) : 0.399 Pa-s
Viscosity reading #3 (C): 0.401 Pa-s
Average viscosity: 0.398 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/26/2024 ✔