Summary for Test 2017-06-14-17-29
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/14/2017 | Sample Unique Key | 17 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2017 |
| Sample type | Quality Assurance | A brief description of the sample | A449 HDG bolt with nut, washer. A325 Bolt |
| The quantity of what the sample constitutes | 12 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Amy | Last name of sampler or witnessed by | Bihary |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Hodell-Natco | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 383381C | |
| Washer Mfg. Lot Number(s) | 1216-412 | Bolt Specification | A449, A325 |
| Bolt Length(s) | 6", 1.25" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 0.625", 1.25" | Bolt Mfg. Lot Number | 44105, 780273 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-06-14-17
DIME Test ID: 2017-06-14-17-29
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-06-30
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/23/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | N/A | 5/8\" | 34410 | 153.06 | Nut Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 6/23/2017 ✔