Summary for Test 2024-05-22-7-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 995007
DEA: 061E7204
EFIS: 0622000092
DIST-CO-RTE-PM06-FRE-41-R27.0/R28.0
Award Date11/16/2023
Closeout Date09/08/2025
Work DescriptionWROUGHT IRON FENCE AND CONSTRUCT SOUND WALL.
Location DescriptionFRESNO COUNTY IN FRESNO AT VARIOUS LOCATIONS FROM DAKOTA AVENUE OVERCROSSING TO GETTYSBURG AVENUE OVERCROSSING
QA Service Level1 (Verified on 07/27/2023)

Sample Information

Sample Taken Date05/22/2024 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/22/2024
Sample typeQuality Assurance A brief description of the sample3/8 concrete aggs
The quantity of what the sample constitutes9cy From where was the sample collectedManufacturer
First name of sampler or witnessed byJonathon Last name of sampler or witnessed byChaney
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Rockfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0014
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-05-22-7
DIME Test ID: 2024-05-22-7-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-05-23

Test Results


What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Tomas Silva
Date of test: 05/22/2024
Sieve SizeCumulative Percent Passing
100 %
89 %
13 %
6 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/23/2024