Summary for Test 2024-05-02-67-1

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 1000330
DEA: 024H0804
EFIS: 0218000075
DIST-CO-RTE-PM02-SIS-96-R0/R16
Award DateNot set
Closeout DateNot set
Work DescriptionSomes Bar CAPM
Location DescriptionIn Siskiyou County at and near Somes Bar from Humboldt County Line to 0.1 mile west of Dillon Creek Bridge
QA Service Level1 (Verified on 05/09/2024)

Sample Information

Sample Taken Date05/02/2024 Sample Unique Key67
Date that the sample was received by the laboratory/organization performing the testing05/02/2024 Sample typePreliminary
A brief description of the sampleSoil for culvert recommendation, C-23 The quantity of what the sample constitutes1 container for culvert recommendation C-23
From where was the sample collectedSource First name of sampler or witnessed byDan
Last name of sampler or witnessed byCurran Title of samplerADME
Telephone number of sampler Laboratory sample identificationD79518
Linked DIME Sample ID The fabricator/manufacturer/facility nameIn Situ
Transportation Laboratory (TL) Number897602 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collected02-SIS-96-15.98 @ INLET
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2024-05-02-67
DIME Test ID: 2024-05-02-67-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2024-05-22

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 05/22/2024
Minimum soil resistance of the lab measurement: 15500 Ohms
Soil sample temperature: 19.9 C
Soil box constant: 1
pH of soil: 5.76
Minimum soil resistance corrected to 15.5: 17205 Ohm-cm
Minimum soil resistivity at 15.5: 17205 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=5.76, p=17205.Ω∙cm

Test was verified on 5/22/2024 ✔