Summary for Test 2024-05-15-44-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 993141
DEA: 060V1204
EFIS: 0616000207
DIST-CO-RTE-PM06-MAD-99-R6.9/R7.6
Award Date06/22/2022
Closeout Date12/02/2025
Work DescriptionCottonwood Creek Bridge Replacement - REPLACE BRIDGES AND CONSTRUCT RETAINING WALLS.
Location DescriptionMADERA COUNTY NEAR MADERA FROM 0.4 MILE SOUTH OF COTTONWOOD CREEK BRIDGE TO 0.1 MILE NORTH OF AVENUE 12 OVERCROSSING
QA Service Level1 (Verified on 07/28/2021)

Sample Information

Sample Taken Date05/15/2024 Sample Unique Key44
Date that the sample was received by the laboratory/organization performing the testing05/17/2024 Sample typeDepartment Acceptance
A brief description of the sampleType II Cement The quantity of what the sample constitutes9.5 CY
From where was the sample collectedJob Site First name of sampler or witnessed byJuan
Last name of sampler or witnessed bydelatores Title of samplerASR
Telephone number of sampler559-240-3566 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBuilders Concrete Ready Mix Plant Sanger
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier41-0089 Structure nameCotton wood Mainline
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberND23502
The truck number from where the sample was collected9128 The batch plant ticket number from where the sample was collected111342774
Concrete batch plantBuilders Concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampledPier 3 columns 6,7,8
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-05-15-44
DIME Test ID: 2024-05-15-44-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-05-22

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 05/20/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 66070 lb
Maximum load on cylinder 2: 62520 lb
Maximum load on cylinder 3: 61990 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 5 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5231.2 psi
Compressive strength of cylinder 2: 4973.7 psi
Compressive strength of cylinder 3: 4931.6 psi
Compressive strength (to nearest 10 psi): 5050 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/22/2024 ✔