Summary for Test 2017-06-06-11-1
Test performed: AGGLP SIEVE_ANALYSIS-1Project Information
| Project Identifiers | Project ID: 212527 DEA: 101F6801 EFIS: 1017000066 |
|---|---|
| DIST-CO-RTE-PM | 10-MPA-120-Var |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Repair of five culverts in Mariposa County along Route 120 with concrete liners. |
| Location Description | In Mariposa County in and near Buck Meadows at various locations. |
| QA Service Level | 1 (Verified on 04/11/2019) |
Sample Information
| Sample Taken Date | 06/06/2017 | Sample Unique Key | 11 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/16/2017 | Sample type | Quality Control |
| A brief description of the sample | Upstream invert of culvert | The quantity of what the sample constitutes | 1 bag |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Ray |
| Last name of sampler or witnessed by | Chang | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | 17SOIL-0175 |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | NA |
| Transportation Laboratory (TL) Number | C703193C | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | na |
| Where the material sample would have been placed if not sampled | 0 to 1 ft |
Test Details
DIME Sample ID: 2017-06-06-11
DIME Test ID: 2017-06-06-11-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-06-28
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 06/21/2017
Total mass of material in the sample: 1603.0 grams
Cumulative mass retained on the 2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 in. sieve: 0.0 grams
Cumulative mass retained on the 3/4 in. sieve: 0.0 grams
Cumulative mass retained on the 1/2 in. sieve: 0.0 grams
Cumulative mass retained on the 3/8 in. sieve: 4.0 grams
Cumulative mass retained on the #4 sieve: 4.0 grams
Cumulative mass retained on the #8 sieve: 1.0 grams
Total sample mass passing the #4 sieve: 1592 grams
Total mass of fine material in the sample: 773 grams
Cumulative mass retained on the pan: 770.0 grams
Total cumulative mass of coarse aggregate: 8 grams
Total cumulative mass of fine aggregate: 771 grams
Sum of coarse and fine aggregate: 1600 grams
Percentage of coarse material: 1 %
Percentage of fine material: 99 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 100 %
Cumulative percent passing the #8 sieve: 100 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/21/2017 ✔