Summary for Test 2024-05-13-61-4

Test performed: AASHTO T313-22

Project Information

Project IdentifiersProject ID: 994975
DEA: 034H0704
EFIS: 0318000158
DIST-CO-RTE-PM03-NEV-20-R12.2/20.0
Award Date10/26/2023
Closeout Date07/15/2025
Work DescriptionCOLD PLANE AND OVERLAY, INSTALL CURED-IN-PLACE PIPELINERS.
Location DescriptionNEVADA COUNTY IN AND NEAR GRASS VALLEY AND NEVADA CITY FROM ROUTE 20/49 SEPARATION TO 0.1 MILE EAST OF CELIO ROAD
QA Service Level1 (Verified on 08/28/2023)

Sample Information

Sample Taken Date05/13/2024 Sample Unique Key61
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/17/2024
Sample typeQuality Assurance A brief description of the samplePG58-22 HMA SP 25% RAP
The quantity of what the sample constitutes1 can From where was the sample collectedSupplier
First name of sampler or witnessed byMichael Last name of sampler or witnessed byChittenden
Title of samplerMaterials Tester Telephone number of sampler5307905033
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Hallwood Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number1
Sublot number1 Tank number
Time of sample HMA SupplierTeichert Hallwood
Certified Asphalt SupplierPacific Northwest Oil - Stockton CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-05-13-61
DIME Test ID: 2024-05-13-61-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T313-22: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2024-05-23

Test Results


Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 05/21/2024
Minimum test bath temperature at 240 s: -12.0 C
Maximum test bath temperature at 240 s: -12.0 C
Time of test load application: no data
File name of test data: no data
Time beam in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficient (R²): 0
Regression coefficient a: no data
Regression coefficient b: no data
Regression coefficient c: no data
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Load at 60.0 s: 0.0 mN
Beam deflection 60.0 s: 0.000 µm
Measured Stiffness Modulus 60.0 s: 132.000 MPa
Estimated Stiffness Modulus 60.0 s: 132.000 MPa
Difference between stiffness moduli 60.0 s: no data
Estimated m-value 60.0 s: 0.350
General comments (publicly viewable) (Max 1000 characters): BBR

Test was verified on 5/23/2024