Summary for Test 2017-06-15-1-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 211777 DEA: 04209504 EFIS: 0412000116 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN,SON-1-50.2/50.5,0.0/0.2 |
| Award Date | 01/04/2017 |
| Closeout Date | 10/21/2019 |
| Work Description | REPLACE ESTERO BRIDGE AND REALIGN APPROACHING ROADWAY; Bridge No. 27-0121 |
| Location Description | MARIN AND SONOMA COUNTIES NEAR VALLEY FORD FROM 0.4 MILE SOUTH OF ESTERO AMERICANO BRIDGE TO 0.2 MILE NORTH OF ESTERO AMERICANO BRIDGE |
| QA Service Level | 1 (Verified on 01/17/2017) |
Sample Information
| Sample Taken Date | 06/15/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Resistance Butt Welded Hoops |
| The quantity of what the sample constitutes | 1500 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Gary | Last name of sampler or witnessed by | MaComb |
| Title of sampler | ASSOC STEEL INSP | Telephone number of sampler | 5622299265 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L10-165-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 65026869-02 |
| Hoop Manufacturer Lot Number(s) | 1, 5, 10 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 8 |
| Diameter of Hoop | 3'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Gerdau |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-06-15-1
DIME Test ID: 2017-06-15-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-06-28
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/21/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 1 | #8/25mm | 0.79 | 75860 | 96030 | Bar Broke at Weld | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke at Weld
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 6/21/2017 ✔