Summary for Test 2024-05-13-42-7
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 993811 DEA: 11422304 EFIS: 1115000180 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-78-0.3/R16.0 |
| Award Date | 10/28/2022 |
| Closeout Date | 06/09/2025 |
| Work Description | CULVERT REPAIRS, COLD PLANE, RHMA-G, MODIFY LANDSCAPE AND ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM 0.3 MILE EAST OF ROUTE 78/5 SEPARATION TO 0.5 MILE WEST OF ROUTE 15/78 SEPARATION |
| QA Service Level | 1 (Verified on 06/13/2022) |
Sample Information
| Sample Taken Date | 05/13/2024 | Sample Unique Key | 42 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2" RHMA-PSU |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0510-PSU | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 21218080SR MM | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-05-13-42
DIME Test ID: 2024-05-13-42-7
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2024-05-22
Test Results
Specified number of passes at 12.7 mm: 20000
Specimen Preparation Method:
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 05/21/2024
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >20000
Stripping Inflection Point (Wheel B): >20000
Maximum impression at 5000 passes (left wheel): 4.92 mm
Maximum impression at 5000 passes (right wheel): 5.16 mm
Average impression at 5000 passes (left/right avg): 5.04 mm
Maximum impression at 10000 passes (left wheel): 5.52 mm
Maximum impression at 10000 passes (right wheel): 5.59 mm
Average impression at 10000 passes (left/right avg): 5.56 mm
Maximum impression at 15000 passes (left wheel): 5.96 mm
Maximum impression at 15000 passes (right wheel): 5.91 mm
Average impression at 15000 passes (left/right avg): 5.94 mm
Maximum impression at 20000 passes (left wheel): 6.3 mm
Maximum impression at 20000 passes (right wheel): 6.36 mm
Average impression at 20000 passes (left/right avg): 6.33 mm
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): Complies < 12.2 mm
Test was verified on 5/22/2024 ✔