Summary for Test 2024-05-08-36-5
Test performed: AASHTO T283-14Project Information
| Project Identifiers | Project ID: 995482 DEA: 112T36U4 EFIS: 1122000243 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-37.4-52.6 |
| Award Date | 10/20/2023 |
| Closeout Date | Not set |
| Work Description | I-5 NCC SEGMENT 4C |
| Location Description | I-5 in San Diego County at Various Locations from Lomas Santa Fe Drive Undercrossing to 0.2 Mile North of Oceanside Undercrossing |
| QA Service Level | 1 (Verified on 11/20/2023) |
Sample Information
| Sample Taken Date | 05/08/2024 | Sample Unique Key | 36 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/09/2024 |
| Sample type | Quality Assurance | A brief description of the sample | HMA-A |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Jesse | Last name of sampler or witnessed by | Fuentes |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0601-JMFV | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan CC | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220817 CC SJR CV | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-05-08-36
DIME Test ID: 2024-05-08-36-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2024-05-22
Test Results
Unit system used?: SI Units
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 05/17/2024
| Wet 1 | Wet 2 | Wet 3 | Dry 1 | Dry 2 | Dry 3 | |
|---|---|---|---|---|---|---|
| Untreated | ||||||
| 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | |
| 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | |
| 3731.6 g | 3717.1 g | 3740.1 g | 3759.6 g | 3754.6 g | 3737.3 g | |
| 2132.2 g | 2119.5 g | 2139.3 g | 2151.2 g | 2157.9 g | 2135.2 g | |
| 3746.4 g | 3732.9 g | 3756.3 g | 3783.0 g | 3770.8 g | 3753.1 g | |
| 2.492 | 2.492 | 2.492 | 2.492 | 2.492 | 2.492 | |
| 3823.0 g | 3808.4 g | 3831.2 g | ||||
| 2132.2 g | 2119.5 g | 2139.3 g | ||||
| 95.2 mm | 95.2 mm | 95.2 mm | ||||
| 225 mmHg | 225 mmHg | 225 mmHg | ||||
| 0 inHg | 0 inHg | 0 inHg | ||||
| 10 minutes | 10 minutes | 10 minutes | ||||
1614.2 cm^3 | 1613.4 cm^3 | 1617.0 cm^3 | 1631.8 cm^3 | 1612.9 cm^3 | 1617.9 cm^3 | |
2.312 | 2.304 | 2.313 | 2.304 | 2.328 | 2.310 | |
7.2 % | 7.5 % | 7.2 % | 7.5 % | 6.6 % | 7.3 % | |
116.2 cm^3 | 121.0 cm^3 | 116.4 cm^3 | 122.4 cm^3 | 106.5 cm^3 | 118.1 cm^3 | |
3812.9 g | 3801.8 g | 3821.6 g | ||||
3824.6 g | 3813.9 g | 3833.2 g | ||||
1690.8 cm^3 | 1688.9 cm^3 | 1691.9 cm^3 | ||||
91.4 cm^3 | 91.3 cm^3 | 91.1 cm^3 | ||||
79 % | 75 % | 78 % | ||||
4.7 % | 4.7 % | 4.6 % | ||||
26323 N | 23871 N | 25700 N | 31454 N | 28474 N | 32183 N | |
2 | 2 | 2 | 2 | 2 | 2 | |
2 | 2 | 2 | 2 | 2 | 2 | |
2 | 2 | 2 | 2 | 2 | 2 | |
1174 kPa | 1064 kPa | 1146 kPa | 1405 kPa | 1272 kPa | 1438 kPa | |
164 psi | 199 psi | |||||
0.82 | ||||||
General comments (publicly viewable) (Max 1000 characters): Complies Target WET>70 and DRY>100
Test was verified on 5/22/2024 ✔