Summary for Test 2024-03-17-13-4
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 214951 DEA: 120K0234 EFIS: 1214000100 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-17.1/18.9 |
| Award Date | 09/23/2020 |
| Closeout Date | Not set |
| Work Description | South County Improvement Project (Phase 3 - El Toro/Alicia) WIDEN FREEWAY AND BRIDGES, RECONSTRUCT BRIDGE AND WALLS. |
| Location Description | ORANGE COUNTY IN MISSION VIEJO, LAGUNA HILLS, LAGUNA WOODS AND LAKE FOREST FROM 0.4 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING TO 0.2 MILE NORTH OF EL TORO ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/01/2020) |
Sample Information
| Sample Taken Date | 03/17/2024 | Sample Unique Key | 13 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/21/2024 |
| Sample type | Production Start-Up | A brief description of the sample | 1/2" HMA-A-SP 15% RAP |
| The quantity of what the sample constitutes | 18 BOXES OF HMA, 4BAGS OF AGGS, I BAG RAP, 4 QTS OF OIL | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | SAM | Last name of sampler or witnessed by | YAMYARI |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0146A-24 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | AAA-Irwindale | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 104775 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-03-17-13
DIME Test ID: 2024-03-17-13-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-17
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 03/25/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1662.0 g
Mass Loss: 90.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.18 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.08 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/17/2024 ✔