Summary for Test 2024-03-17-13-4

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214951
DEA: 120K0234
EFIS: 1214000100
DIST-CO-RTE-PM12-ORA-5-17.1/18.9
Award Date09/23/2020
Closeout Date02/09/2026
Work DescriptionSouth County Improvement Project (Phase 3 - El Toro/Alicia) WIDEN FREEWAY AND BRIDGES, RECONSTRUCT BRIDGE AND WALLS.
Location DescriptionORANGE COUNTY IN MISSION VIEJO, LAGUNA HILLS, LAGUNA WOODS AND LAKE FOREST FROM 0.4 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING TO 0.2 MILE NORTH OF EL TORO ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/01/2020)

Sample Information

Sample Taken Date03/17/2024 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing03/21/2024 Sample typeProduction Start-Up
A brief description of the sample1/2" HMA-A-SP 15% RAP The quantity of what the sample constitutes18 BOXES OF HMA, 4BAGS OF AGGS, I BAG RAP, 4 QTS OF OIL
From where was the sample collectedManufacturer First name of sampler or witnessed bySAM
Last name of sampler or witnessed byYAMYARI Title of sampler
Telephone number of sampler Laboratory sample identification0146A-24
Linked DIME Sample ID The fabricator/manufacturer/facility nameAAA-Irwindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number104775
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-03-17-13
DIME Test ID: 2024-03-17-13-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-17

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 03/25/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1662.0 g
Mass Loss: 90.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.18 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.08 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/17/2024 ✔