Summary for Test 2024-05-16-2-2
Test performed: AASHTO T275-07r12Project Information
Project Identifiers | Project ID: 214135 DEA: 09213404 EFIS: 0900000030 |
---|---|
DIST-CO-RTE-PM | 09-INY-395-29.9/41.8 |
Award Date | 10/22/2021 |
Closeout Date | Not set |
Work Description | ROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT. |
Location Description | INYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE |
QA Service Level | 1 (Verified on 05/03/2019) |
Sample Information
Sample Taken Date | 05/16/2024 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/16/2024 |
Sample type | Quality Assurance | A brief description of the sample | HMAR-76 A,B,C |
The quantity of what the sample constitutes | 250 Each | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jerid | Last name of sampler or witnessed by | Kupelian |
Title of sampler | Materials Tech 2 | Telephone number of sampler | 8058042482 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Fisher Sand & Gravel Olancha plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | roadway paving first lift |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 76 |
Test Details
DIME Sample ID: 2024-05-16-2
DIME Test ID: 2024-05-16-2-2
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2024-05-17
Test Results
Number of tests: 3
What test procedure is performed?: Method A
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 05/17/2024
Mass of the dry specimen in air: 881.7 g
Mass of the dry specimen plus paraffin coating in air: 901 g
Mass of the dry specimen plus paraffin coating in water: 506.7 g
Specific gravity of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Mass 2 of the dry specimen in air: 1157.5 g
Mass 2 of the dry specimen plus paraffin coating in air: 1182.9 g
Mass 2 of the dry specimen plus paraffin coating in water: 663.3 g
Specific gravity 2 of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Mass 3 of the dry specimen in air: 1320.4 g
Mass 3 of the dry specimen plus paraffin coating in air: 1348.1 g
Mass 3 of the dry specimen plus paraffin coating in water: 774.1 g
Specific gravity 3 of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Bulk Specific Gravity: 2.365
Bulk Specific Gravity 2: 2.356
Bulk Specific Gravity 3: 2.431
Average Bulk Specific Gravity: 2.384
General comments (publicly viewable) (Max 1000 characters): Cores R76
Test was verified on 5/17/2024 ✔