Summary for Test 2024-02-16-11-4

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215349
DEA: 081C0824
EFIS: 0816000087
DIST-CO-RTE-PM08-RIV-10-R104.9/R134.2
Award Date03/24/2021
Closeout Date01/06/2025
Work DescriptionPLACE HMA (TYPE A), JPCP AND IMPORTED BORROW.
Location DescriptionRIVERSIDE COUNTY FROM ROUTE 10/177 SEPARATION TO 1.1 MILES WEST OF WILEY'S WELL RD OC
QA Service Level1 (Verified on 03/01/2021)

Sample Information

Sample Taken Date02/16/2024 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/20/2024
Sample typeProduction Start-Up A brief description of the sample3/4" HMA-A-SP- R24 1.00 LMS
The quantity of what the sample constitutes20 BOXES OF HMA-A, From where was the sample collectedManufacturer
First name of sampler or witnessed byJareerattana Last name of sampler or witnessed bySirisujarittham
Title of samplerQC Telephone number of sampler
Laboratory sample identification0123A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameFisher Sand and Gravel-Tempe Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberCA125MA
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-02-16-11
DIME Test ID: 2024-02-16-11-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-17

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 02/22/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2103.0 g
Mass Loss: 110.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.02 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.07 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.19 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/17/2024