Summary for Test 2024-05-13-43-10

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 993811
DEA: 11422304
EFIS: 1115000180
DIST-CO-RTE-PM11-SD-78-0.3/R16.0
Award Date10/28/2022
Closeout DateNot set
Work DescriptionCULVERT REPAIRS, COLD PLANE, RHMA-G, MODIFY LANDSCAPE AND ELECTRICAL.
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM 0.3 MILE EAST OF ROUTE 78/5 SEPARATION TO 0.5 MILE WEST OF ROUTE 15/78 SEPARATION
QA Service Level1 (Verified on 06/13/2022)

Sample Information

Sample Taken Date05/13/2024 Sample Unique Key43
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2024
Sample typeQuality Assurance A brief description of the sample1/2" RHMA-PSU
The quantity of what the sample constitutes2 Bags From where was the sample collectedSupplier
First name of sampler or witnessed byBen Last name of sampler or witnessed bySmith
Title of sampler Telephone number of sampler
Laboratory sample identification0510-PSU Linked DIME Sample ID2024-05-13-42
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Lakeside
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-05-13-43
DIME Test ID: 2024-05-13-43-10
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-05-22

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 05/16/2024
Cumulative Mass RetainedCumulative Percent Passing
3597 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
20.0 grams99 %
747.0 grams79 %
2050.5 grams43 %
634.2 grams
170.6 grams31 %
337.4 grams20 %
469.4 grams11 %
573.3 grams4 %
619.5 grams1 %
633.9 grams0 %
634.9 grams
General comments (publicly viewable) (Max 1000 characters): Failed Coarse Aggs

Test was verified on 5/22/2024