Summary for Test 2024-04-30-58-1
Test performed: AASHTO T275-07r12Project Information
| Project Identifiers | Project ID: 213306 DEA: 07303404 EFIS: 0714000006 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-33-0.0/6.3 |
| Award Date | 06/18/2018 |
| Closeout Date | 05/10/2021 |
| Work Description | COLD PLANE AC PVMT, PLACE RUBBERIZED AC (TYPE G), AND REPLACE PCC PVMT |
| Location Description | VENTURA COUNTY IN AND NEAR VENTURA FROM ROUTE 33/101 SEPARATION TO 0.1 MILE SOUTH OF PARK VIEW DRIVE |
| QA Service Level | 1 (Verified on 12/09/2020) |
Sample Information
| Sample Taken Date | 04/30/2024 | Sample Unique Key | 58 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/10/2024 |
| Sample type | Department Acceptance | A brief description of the sample | 4-inch dia. HMA core |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Garrett | Last name of sampler or witnessed by | Granger |
| Title of sampler | G3 Material tester | Telephone number of sampler | |
| Laboratory sample identification | 24-080 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Materials Sun Valley | Transportation Laboratory (TL) Number | 3234041 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220826 SVA SJR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-04-30-58
DIME Test ID: 2024-04-30-58-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2024-05-16
Test Results
Number of tests: 3
What test procedure is performed?: Method A
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 05/14/2024
Mass of the dry specimen in air: 1670.0 g
Mass of the dry specimen plus paraffin coating in air: 1690.3 g
Mass of the dry specimen plus paraffin coating in water: 965.5 g
Specific gravity of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Mass 2 of the dry specimen in air: 1228.3 g
Mass 2 of the dry specimen plus paraffin coating in air: 1244.4 g
Mass 2 of the dry specimen plus paraffin coating in water: 717.0 g
Specific gravity 2 of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Mass 3 of the dry specimen in air: 1162.0 g
Mass 3 of the dry specimen plus paraffin coating in air: 1179.6 g
Mass 3 of the dry specimen plus paraffin coating in water: 668.4 g
Specific gravity 3 of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Bulk Specific Gravity: 2.378
Bulk Specific Gravity 2: 2.411
Bulk Specific Gravity 3: 2.363
Average Bulk Specific Gravity: 2.384
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/16/2024 ✔
