Summary for Test 2017-06-06-7-43

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/06/2017 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing06/09/2017 Sample typeQuality Assurance
A brief description of the sampleF1554 anchor rods, A325 Bolt Assembly The quantity of what the sample constitutes27
From where was the sample collectedDistributor First name of sampler or witnessed byKevin
Last name of sampler or witnessed byChurchill Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameUniversal Industrial Sales Unytite, Prestige,
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL0204017
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0085815, TT0085814
Heat Number(s)PL16102621 Nut Mfg. Lot Number(s)23501-166333, 23220-6214073903
Washer Mfg. Lot Number(s)D0217, D2048, Z1B-A Bolt SpecificationA325, F1554
Bolt Length(s)5", 2.75", 3'-4" Nut SpecificationA563
Washer SpecificationF436, F959 FinishMG, HDG
Diameter/Size1.5", 0.625", 2.5" Bolt Mfg. Lot Number22640-75061539, BM0107
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2017-06-06-7
DIME Test ID: 2017-06-06-7-43
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-06-21

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Arnold
Date of test: 06/14/2017
UTM: 400KIP
Temperature: 71 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
12AL02040175/8\"34452153.25Nut Proof LoadArnold

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 6/14/2017 ✔