Summary for Test 2024-01-04-56-1
Test performed: ASTM C39-21Project Information
Project Identifiers | Project ID: 994326 DEA: 051C3604 EFIS: 0512000134 |
---|---|
DIST-CO-RTE-PM | 05-SB-217-0.9/1.4 |
Award Date | 01/31/2023 |
Closeout Date | Not set |
Work Description | REPLACE BRIDGE. |
Location Description | SANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE |
QA Service Level | 1 (Verified on 10/17/2022) |
Sample Information
Sample Taken Date | 01/04/2024 | Sample Unique Key | 56 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/04/2024 |
Sample type | Quality Control | A brief description of the sample | QC Sampling Data |
The quantity of what the sample constitutes | 26CY | From where was the sample collected | Source |
First name of sampler or witnessed by | Connor | Last name of sampler or witnessed by | Pelan |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | KIE-CON, INC | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | K5070-4212 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 120442 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-01-04-56
DIME Test ID: 2024-01-04-56-1
Testing Lab: Kie-Con, Incorporated - Antioch
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-05-16
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With density determined by dimension measurements
Input Type: Calculated
Tester's full name: Connor Pelan
Date of test: 02/01/2024
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Average cylinder density (to nearest 1 pcf): 0 lb/ft^3
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters): 28 day strength of 9,450psi
Test was verified on 5/16/2024 ✔